Smart electricity & water meters with leak alarm
MID-certified electricity meters and smart water meters with remote reading. Data collection and leak alarms – local and across the distribution grid.
One Swedish collection system. The entire meter fleet.
The meters are just the start. The value is in the collection: one system that brings home every reading, alerts when something deviates and delivers data where you want it. Developed and operated in Sweden, for electricity and water in one platform.
The chain runs from meters to your systems: electricity and water meters in buildings, substations and the distribution network report to a data concentrator (DCU) that gathers up to 500 meters and forwards the readings securely. The collection system validates, stores and alerts in real time, and delivers the data via APIs and exports to billing, EMS and analytics. The data is yours.
We meter both electricity and water. MID-certified electricity meters and smart water meters report into our Swedish data collection system, which gathers real-time data, handles remote reading and alerts on leaks. That is the foundation for accurate billing in a housing co-op and for seeing where electricity and water actually go.
Frequently asked questions
Are your meters used in Sweden today?
Yes, we have delivered and installed meters for several municipalities and electricity companies across Sweden. We can demonstrate strong results with high customer satisfaction and reliability.
Which communication protocols are supported?
We support MQTT and Modbus protocols for seamless integration with existing systems and real-time communication for monitoring and control.
How long does the calibration last?
Our meters have 20-year calibration stability, meaning minimal drift and long-term reliability without the need for frequent recalibration.
Do you also install the meters?
Yes, we have completed over 40,000 installations with associated infrastructure. We can showcase successful projects and reference customers.
What is a HAN port (P1 port) on the electricity meter?
The HAN port, also called the P1 port, is a standardized customer interface on smart electricity meters that gives local access to the meter's real-time data – for example current power, voltage and current per phase. Our 3-phase meter STZ351 is equipped with a P1 HAN port, so you can connect your own equipment for energy monitoring and control.
What is the difference between 1-phase and 3-phase electricity meters?
A 1-phase meter (our STZ131, 230 V) is used for single-phase connections, such as apartments and smaller premises. A 3-phase meter (our STZ351, 230/400 V) is required for three-phase connections in properties, farms and industry. Both measure up to 100 A, have a replaceable communication module and support RS485, G3-PLC, RF, 4G, Wi-SUN and NB-IoT, among others.
Are your smart electricity meters suitable for properties and businesses?
Yes. For property companies and housing associations we deliver MID-approved metering per apartment with remote reading, enabling billing based on actual consumption. For businesses and industry, the 3-phase meter measures power (kW), power factor and power quality (THD). Our TG30 data concentrator manages over 500 meters remotely within the same installation.
Can the meters be used for power measurement ahead of the power tariffs?
Yes. The meters measure active and reactive energy as well as power (kW) per phase in real time – exactly the data needed to track and shave power peaks as the grid operators' power tariffs arrive by 2027. Combined with our control system and a battery storage unit, the metering data can drive automatic peak shaving.
Do you also offer smart water meters?
Yes. We supply smart water meters with remote reading and a complete data collection system for the entire meter fleet – the same platform as our electricity meters.
How does the leak alarm work?
The water meters alert on leaks both locally at the customer (continuous flow, freeze, backflow) and across the distribution network via night-flow analysis and zoning. This reduces water loss and shortens time to response.